Triton RAB-PO-X68-XN Manuale Utente
103
400
900
600
70
300
390
390
500
19"
2U
6U
19"
19"
12U
155
70
400
900
600
70
300
390
390
500
19"
2U
6U
19"
19"
12U
155
70
RFa
BREaKOUT-TYPE BlaNKING PaNElS
There are two breakout-type blacking panels in the left steel
door for installation of cooling ventilators RAB-CH-X30-X1.
door for installation of cooling ventilators RAB-CH-X30-X1.
1. SECTION
19“ equipment with max. height of 6U and depth of 230 mm can
be installed into the first section. The equipment is placed vertically
and 19“ rails can be adjusted in predefined positions. Power
distribution panel 230V, supply adapters for active components
or eventually data incoming lines, are typical devices installed in
this section.
be installed into the first section. The equipment is placed vertically
and 19“ rails can be adjusted in predefined positions. Power
distribution panel 230V, supply adapters for active components
or eventually data incoming lines, are typical devices installed in
this section.
2. SECTION
The mounting width of 19“ , height 12U and depth of 230 mm
are at the disposal in the second section, where mounting rails are
infinetely adjustable. Structured cabling system and active network
components are usually concentrated in this section. Distribution
of particular services to working places come out of this place.
Recommended capacity is up to 48 working places (two ports for
each according to the standards).
are at the disposal in the second section, where mounting rails are
infinetely adjustable. Structured cabling system and active network
components are usually concentrated in this section. Distribution
of particular services to working places come out of this place.
Recommended capacity is up to 48 working places (two ports for
each according to the standards).
3. SECTION
t
he third section occupies the whole area of cabinet rear side.
There is a place for equipment with max. dimensions of 19“,
height 2U and depth 800 mm, installed vertically. Side perforated
door on the cabinet right side enables access to this section. Server
1U or 2U can be installed into this section. enough place provided
with the side door allow extension of the whole server on the side
(in case of telescopic slides). It is necessary to consider sufficient
space from the both sides yet before installing. Because of server
installation on the right side and metal door of the first section on
the left side. Cooling of installed equipment can be supported by
installation of ventilators RAX-CH-X07-X9. There are two break-
out blanking panels in the left perforated door for it`s mounting.
height 2U and depth 800 mm, installed vertically. Side perforated
door on the cabinet right side enables access to this section. Server
1U or 2U can be installed into this section. enough place provided
with the side door allow extension of the whole server on the side
(in case of telescopic slides). It is necessary to consider sufficient
space from the both sides yet before installing. Because of server
installation on the right side and metal door of the first section on
the left side. Cooling of installed equipment can be supported by
installation of ventilators RAX-CH-X07-X9. There are two break-
out blanking panels in the left perforated door for it`s mounting.
RFa
TYPe
Weight gross (kg)
Weight net (kg)
maximal recommended load (kg)
RFA-12-A94-CAX-A1
27,3
26,9
50