12 
power cable.   
③ 
Connect the SU-200BX test unit to the MM-202BX UPLINK port using a RJ-45 cable. 
④ 
Connect the S U-200BX power cable to a power outlet from the same phase as the 
installed MM-202BX. 
⑤ 
Turn on the power of the MM-202BX. 
⑥ 
Using a long sharp instrument, push down on the reset button of the SU-200BX to. 
⑦ 
Turn on the power of the SU-200BX while the reset button is pushed down. 
⑧ 
Check if the ACT LED is blinking. 
⑨ 
Disconnect the RJ-45 cable from the SU-200BX and MM-202BX. 
⑩ 
Reconnect the MM-202BX cables to their original positions. 
⑪ 
Reset the power of the SU-200BX.   
⑫ 
Connect the laptop PC to the LAN port of the SU-200BX and configure the network 
properties. 
⑬ 
Confirm if the Internet connection is working properly.  
 
4.6 Resetting to Factory Default Mode 
Use the reset button at the top side of the MM-202BX in order to reset the configuration into 
factory default mode.   
① 
Turn off the power of the MM-202BX. 
② 
Disconnect all cables (including CU-100A cables) from the MM-202BX except for the 
power cable. 
③ 
Use a long sharp instrument (such as a tweezers) in order to push down on the reset 
button on the top side of the MM-202BX. 
④ 
Turn on the MM-202BX while pushing down on the reset button. 
⑤ 
Using the  sharp instrument, push  down on the reset button for 1 second.  Wait at 
least 1 second before repeating the procedure at least 3 times or more. 
⑥ 
The ACT 2 LED will blink when the MM-202BX is changed to the factory default mode. 
⑦ 
Reset the power of the MM-202BX.