Xeline Co. LTd. MM-202BX Manuale Utente

Pagina di 14
                                
MM-202BX 
Installation Manual
 
This document is subject to change without prior notice.
 
 
13 
5. Trouble Shooting                                                
 
Power 
Problem 
Checklist 
The PWR LED does not 
activate. 
① 
Check if the power cable is firmly plugged into the MM-
202BX and power outlet.   
② 
Check if the Hot line and Neutral line is correctly 
connected to the power outlet. 
Ethernet Connection 
Problem 
Checklist 
The UPLINK LED does not 
activate. 
① 
Check if the RJ-45 cable is firmly plugged into the UPLINK 
port of the MM-202BX and the Switch Hub.   
② 
Check if the Switch Hub is operating normally.  
The network connection 
icon in the PC icon tray is 
disabled.   
① 
Check if the RJ-45 cable is firmly plugged into the LAN 
port of the MM-202BX and NIC of the laptop PC. 
② 
Check if the NIC connection is disabled in the Local Area 
Network window.  
Internet access is not 
possible. 
① 
Try connecting the laptop PC directly to the Switch Hub 
and recheck the Internet accessibility.   
② 
Check the IP configuration of the  laptop PC.  If the  IP 
configuration is correct, the problem  lies in the ISP 
backbone.   
PLC Connection 
Problem 
Checklist 
The ACT1 and ACT2 LEDs  
of the  MM-202BX do not 
activate. 
① 
Check if the RJ-11 cable is firmly plugged into the  SIG2 
port of the MM-202BX and the INPUT port of the CU-100A. 
② 
Check the coupling procedures of the CU-100A are 
correctly done. For details concerning the coupling 
methods, refer to the CU-100A Installation Guide
③ 
Check if the  SU-200BX test unit is plugged into an outlet 
that is from the same phase as the powerlines coupled to 
the CU-100A.  (This procedure is not necessary if multi-
phase coupling method is used.) 
Internet access is not 
possible. 
This can occur when the  SU-200BX test unit configuration has 
not been correctly downloaded. Reset the  SU-200BX to the 
factory default mode and download the configuration again.   
If the problem is still not solved, please contact Xeline’s Technical Support Center.