Installation
MC-Series High-Power System
998--01
Rev
X1
46
CONFIDENTIAL AND PROPRIETARY
RadioFrame Networks, Inc.
TRADE SECRET INFORMATION
Figure 27 Connections between the Primary iSC and BIC
4.3.2 EAS
Note: Typically, the EAS is installed by RadioFrame Networks before the MC-Series
High-Power system is shipped. If you need to install an EAS, follow this procedure:
1 While supporting the EAS, slide the EAS into the cabinet mounting position.
2 Mount the EAS in the location shown in Figure 26.
3 Secure the EAS to the cabinet mounting rails using the four mounting screws
2 Mount the EAS in the location shown in Figure 26.
3 Secure the EAS to the cabinet mounting rails using the four mounting screws
provided with the unit. Tighten the screws to 4.5 Nm (40 in-lb).
4 Connect the RFN-provided ground cable (P/N 820-0609-10; EAS to GND BAR)
between the cabinet ground bar and the grounding lug on the rear of the EAS, and
ensure the connection is tight.
ensure the connection is tight.
5 Connect the RFN-provided power cable (P/N 820-0616-50; EAS to PDU-EAS)
between the EAS power and the EAS circuit breaker on the PDU.
6 Connect EAS to each iSC-3 according to Sprint Nextel’s installation procedure.
7 Refer to Figure 28. Connect the RFN-provided contact closure alarm wires from the
7 Refer to Figure 28. Connect the RFN-provided contact closure alarm wires from the
CONTROL port on the EAS (RJ-45) to the STATUS connectors on the PDU
(Molex).
(Molex).
Figure 28 Connection between EAS Control Port and PDU Status Connectors