Chapter 5  Diagnostics and Troubleshooting 
Testing 
Equipment 
Management 
Station
E1
Interface
/T1
Local ODU
 
Figure 5-3.  Local External Loopback 
Remote Internal Loopback 
Remote WinLink 1000 can be set to an internal loopback to test 
connection between the local and remote units, the local E1/T1 port 
and its connection to the local side user equipment. In this mode, data 
coming from the local WinLink 1000 is looped back to it (see 
). This loopback is initiated from a management station connected to 
the local unit. 
Management 
Station
E1/T1
Interface
E1
Interface
/T1
Testing 
Equipment
Remote ODU
Local ODU
 
Figure 5-4.  Remote Internal Loopback 
Remote External Loopback 
Remote WinLink 1000 can be set to an external loopback to test the 
remote E1/T1 port and its connection to the remote side user 
equipment. In this mode, data coming from the remote user equipment 
is looped back to it (see 
). This loopback is initiated by an 
inband command sent from a management station connected to the 
local unit. 
 PM 
Running Diagnostic Loopbacks 
5-5