ZTE Corporation R8978S2600L Manuale Utente

Pagina di 66
ZXSDR R8978 User Manual
Tool
Function
M5 cross screw driver
Installs or uninstalls the ZXSDR R8978 maintenance cavity
Sticker
Marks the connection of the cables to be replaced (after the
replacement, all the cables must be reconnected to the place
where they were)
Moisture-proof antistatic bag
and carton
Stores the faulty optical module
Steps
1.
Open the cover of the maintenance cavity by using the M5 screw driver.
2.
Paste a label at each end of every optical fiber.
3.
Press the blue clamp of the fiber, and pull the fiber connector out of the optical module
to be replaced.
4.
Pull the optical module out of the slot.
5.
Install the proper optical module into the slot.
6.
Remove the dustproof cap, and connect the fiber connector to the new optical module.
7.
Check whether the optical module is operating properly in accordance with the
indicator status.
8.
Tighten the fiber clamp and close the maintenance cavity.
– End of Steps –
4.6.3 Replacing the RF Cable
The RF cable transmits or receives RF signals. Locate the faults through observation and
analysis, and ensure that whether to replace the RF cable. Replacing the RF cable will
interrupt all the services carried by the ZXSDR R8978.
Prerequisite
l
Prepare a proper RF cable to be replaced.
Each site has a set of RF cables corresponding to the site type.
à
For BTS expansion or modification, you can select a set of RF cables
corresponding to the site type.
à
For replacement of a single RF cable, you can select a proper RF cable from the
RF cable set.
Check whether the core connector of the RF cable is proper.
l
Prepare the following tools.
4-8
SJ-20141113151137-001|2016-08-17 (R1.2)
ZTE Proprietary and Confidential