ZTE Corporation RSU60EGU858 Manuale Utente

Pagina di 37
Chapter 4 RSU60E
The business data from
BBU
enters the ADTR, and then for intermediate frequency
processing. After the power amplification sent to the antenna for transmission.
l
Reverselink processing
The reverse GSM&UMTS signals from the antenna are converted to baseband digital
signal by ADTR, then send to
BBU
.
4.3.3 Technical Specifications
4.3.3.1 Physical Indices
4.3.3.1.1 Dimension
The dimensions of ZXSDR RSU60E in mm are : 482.6(H) × 88 (W) × 360.0 (D).
4.3.3.1.2 Weight
Weight of a ZXSDR RSU60E : < 15 kg (33.1 pounds).
4.3.3.2 Power
l
Power Supply
-48 V DC Voltage range: -40 V~ -57 V.
l
Power Consumption
The total power consumption of the equipment is 360 W.
4.3.3.3 Capacity Indices
ZXSDR RSU60E Capacity Indices is shown as
Table 4-4 ZXSDR RSU60E Capacity Indices
Item
Carriers supported
1
GSM 6C(max Single RAT)
2
UMTS 3C(max Single RAT)
3
2GMS+2UMTS;4GSM+1UMTS
4.3.3.4 Temperature and Humidity
Temperature: -5 ℃ ~ +45 ℃. The change frequency must be less than 0.5 ℃/min.
Relative humidity: 5% ~95%
4.3.3.5 Reliability Indices
l
Mean Time Between Failures (MTBF) : > 100,000 hours
l
MTTR (Mean Time To Repair): < 0.5 hour
4-13
SJ-20110823164828-001|2011–08–16
ZTE Proprietary and Confidential