-48V DC Voltage range: -40V~-57V.
l
Power Consumption
In the case of 2S-2T, 4C/S, 15W/C, the total power consumption of the equipment is
600 W.
3.3.3 Capacity Indices
ZXSDR RSU82C Capacity Indices is shown as
Table 3-2 ZXSDR RSU82C Capacity Indices
Item
Carriers supported
1
4C 1X + 4C 1X
2
4C 1X + 4C DO
3
4C DO + 4C DO
4
the MAX 8C/2S-2T
3.3.4 Temperature and Humidity
Temperature: -40 ℃~+55 ℃. The change frequency must be less than 0.5 ℃/min.
Relative humidity: 5% ~95%
3.3.5 Environmental Classes
l
Grade Of Protection: IP55
l
Grounding Requirements:
Joint grounding resistance less 1W; BTS grounding
resistance less 5 W.
l
Noise: Noise of working environment: less 65 dBA
3.3.6 Reliability Indices
l
Mean Time Between Failures (MTBF) : > 100,000 hours
l
MTTR (Mean Time To Repair): < 0.5 hour
l
Availability: > 99.999%
3.3.7 RF Indices
RF indices of the ZXSDR RSU82C comply with 3GPP2 C.S0010-C, Recommended
Minimum Performance Standards for cdma2000 Spread Spectrum Base Station and
3GPP2 C.S0032-A, Recommended Minimum Performance Standards for CDMA2000
High Rate Packet Data Access Network.
illustrates the 1.9 GHz transmitter indices.