2.  Mount the cabinet on the installation plate, and insert the 4 
hex flange bolts at the back of the cabinet through the larger 
parts of the cucurbit holes on the plate. 
3.  Move the inserted 4 hex flange bolts into the smaller parts of 
the cucurbit holes to fix the cabinet to the plate. 
4.  Tighten the 4 hex flange bolts. 
Note:
 The diameter of the pole should be within the range of 30 
mm (1 3/16 in) to 60 mm (2 6/16 in). 
E
ND OF 
S
TEPS
External Cables Installation 
The external cable installation includes: 
 
Grounding cable installation 
 
Ethernet cable installation 
 
Power cable installation 
 
GPS RF cable installation 
Grounding Cable Installation 
The following describes prerequisites and procedure of 
grounding cable installation. 
The connection point for the indoor grounding copper bus-bar is 
available. 
Prepare a length-proper grounding cable according to the actual 
situation. Use a 16mm
2
 (6 AWG) olivine copper cable to make 
the grounding cable. 
Crimp a bare round metal terminal (also called lug) at both ends 
of the cable respectively. 
Perform the following steps to install the grounding cable. 
1.  Connect one bare terminal of the grounding cable to the 
protective grounding terminal that is located at the M5 bolt 
of the power cable interface on the ZXMBW E9200 cabinet. 
2.  Connect the other end of the grounding cable to the specified 
indoor grounding copper bus-bar. 
Note:
 To ensure reliable connection, press the lugs of grounding 
cable to make the cable in good contact with the other parts. 