S610S Manual  - Hardware Installer Manual  - Version 1.8 
 
15 
Note: Other inputs, including lock status can be fitted with a resistor network in the same 
way. 
Enable 4-state tamper detect 
Use the workstation AC2000 Devices application.  From the table, select the device the sensor is 
connected to.   
Under 
Configuration
 select the 
Inputs
 tab.  Select 
Each Input
 that needs to be configured for 4 state 
from the list and check 
4 state
. 
3.7  Using an external read head 
In some exceptional circumstances it may be necessary to connect an external read head to the 
reader for dual technology access.  For example a barcode reader can be connected to H0 to allow 
access to barcode type cards, as well as Prox card holders. 
To connect an external read head to the secure side of a door use H0 head connection found on 
the reader PCB.  H0 pin order is shown below; the reader wires are for a sample only. 
 
To connect a read head for an Exit reader use H1.  See connecting an Exit Reader later in this 
manual.  
3.8  S610S Lock and spare output relay connections 
The S610E reader has two volt-free changeover relays. 
The following S610S parameters may be changed using the Devices application if required: - 
lockopentime (sec)
 - maximum time to open the door after a valid card presentation 
doorcloseafter (sec)
 - maximum time for door to remain open before an alarm is generated 
Connecting a lock 
In normal door mode Relay 0, the first relay, is reserved for a door lock.  A door lock controlled 
by Relay 0 does not require any AC2000 workstation software configuration; unless changes to 
the default five second 
Lock open time
 is necessary.  Relay 1, the second relay, (if not used for 
Interlocking) is spare and can be used to activate an external device e.g. sounder or strobe light.   
Connect a maglock or a lock that is secure when electrically energised to the relay output 
connector J12 as follows: 
 
Relay Connector J12 showing typical Maglock configuration. 
HEAD0-12V
RED0
GREEN0
AMBER0
HEAD GND
WIEGO-D1
WIEGO-D0
5volts
READ HEAD
READ HEAD
H0
LABEL
  
WHT- DATA1/CLOCK
 
GRN - DATA0/DATA
BLK - GND
ORN - GREEN LED
BRN - RED LED
RED - 5.0 - 16.0 VDC
J2