Alarm Configuration 
Any Alarm required for notification on an Alarm Event Display (AED) as a result of an Equipment 
Enable reader input changing state will have to be setup in an AC2000 workstation application 
Alarm configuration. 
7.10  Multiple badge access  
Multiple badge access, or No Lone Zone, allows the reader to be configured to require more than 
one valid card transaction, before access is granted.  The purpose is to deny individuals being alone 
in restricted or highly secure areas, and to ensure persons can only enter or exit the area when 
escorting each other.  Two or more different valid card transactions are required, up to a maximum 
of five.    The biometric S610F fingerprint reader also supports this configuration.  Reader firmware 
version B1.00.030 or higher is needed. 
Two configurations are required:  
AC2000 Device application: select the reader, then 
configured > other> multi swipe mode
 
1. 
Set the number of different valid cards required to allow access 
2. 
Set the time allowed for all the required entry or exit transactions to take place. 
When the time allowed is set to 
0
   Multiple Badge Access is turned OFF, i.e. the reader will release 
the lock with a single card swipe. 
Where an Exit reader is fitted the rule applies to that also.  If two cards are swiped and one person 
leaves the area, the other person will be unable to leave on their own.  To open the door it will 
require two different transactions on the “Entry” reader to release the person on the secure side.