Redline Communications Inc. AN80IC Manuale Utente

Pagina di 94
 
Red
CONNEX
™   
 
User
 
 
AN-80i
 
Manual
 
 
70-00072-01-05-DRAFT 
Proprietary Redline Communications © 2008
 
Page 26 of 94 
January 22, 2008 
IP Subnet Mask: Enter the IP subnet mask. 
Default Gateway Address: Enter the IP address of the default gateway or router on the 
Ethernet segment connected to the AN-80i Ethernet port. 
Flow Control Enable: Check this box 
 to enable flow control functions (802.3x) on 
the AN-80i Ethernet port. Enabling this feature allows the AN-80i to request Ethernet 
devices to pause transmissions during busy periods. 
Prioritized Low Latency Mode Enable: Check this box 
 to enable priority handling 
of 802.1p tagged traffic. When enabled, this ensures prioritized traffic is transmitted with 
the lowest achievable latency, even under conditions of high IP data traffic loading. 
Table 3
: Configuration - 802.1p Priority Settings 
Priority Setting 
Highest  
6, 7 
 4, 
 
0, 3, no tag 
Lowest  
1, 2 
 
SNTP Enable: Check this box 
 to enable the SNTP protocol support. This feature 
allows AN-80i systems to time-stamp log messages using a network time server. When 
enabled, you must enter the network address of the SNTP server in the SNTP Server IP 
Address field.  
SNTP Server IP Address: Enter the network address of the SNTP server. Valid only 
when the SNTP Enable field is checked. 
Polling Interval: Enter the SNTP polling interval (hours). 
Time Zone (GMT): Enter the hours offset from GMT for this time zone. Valid only 
when the SNTP Enable field is checked. 
Syslog Enable: Check this box 
 to enable the Syslog protocol support. This feature 
allows AN-80i log messages to be saved in a central repository. When enabled, you must 
enter the network address of the Syslog server in the Syslog Server IP Address field. 
Syslog Server IP Address: Enter the network address of the Syslog server. Valid only 
when the Syslog Enable field is checked. 
Ethernet Mode: Select the operating mode of the Ethernet port. 
Auto - Auto-negotiate the speed connection speed. 
10 - Operate at 10Base-T only. 
100 - Operate at 100Base-T only. 
HD - Operate at half-duplex only. 
FD - Operate in full duplex only. 
Important: The auto-negotiate feature does not detect the speed and duplex of 
manually set Ethernet equipment. The auto-negotiate feature works correctly only 
when both communicating Ethernet devices are configured for auto-negotiate. Duplex 
mismatches may result in an unexpected loss of communications.
 
 
HTTP Enable: Check this box 
 to enable the HTTP (Web) interface. If the option is 
deselected, only CLI commands will be available.