Redline Communications Inc. AN80IC Manuale Utente

Pagina di 94
 
Red
CONNEX
™   
 
User
 
 
AN-80i
 
Manual
 
 
70-00072-01-05-DRAFT 
Proprietary Redline Communications © 2008
 
Page 27 of 94 
January 22, 2008 
Telnet Enable: Check this box 
 to enable a Telnet access (CLI) to the AN-80i. Refer to 
the CLI commands in CLI Interface on page 62. 
Telnet Port: Enter Telnet port address (default is 23). 
SNMP Enable: Check this box 
 to enable the Simple Network Management Protocol 
(SNMP) agent. When this item is checked, click on the blue text 
[
Configure
 
SNMP
]
 
adjacent to the check box to display the SNMP Configuration screen. 
Mgmt. Tag Enable: Check 
 this box to enable VLAN tagged traffic. 
The Mgmt Tag Enable setting is disabled (factory default) when shipped from the factory 
or following a long-reset operation. In this mode the PTP Master and PTP Slave can be 
managed through the local Ethernet port using untagged traffic. Over-the-air management 
is possible only after creating a pass-through group and pass-through connections for 
each PTP Slave. 
When Mgmt Tag Enable is enabled, this PTP Master or PTP Slave can be managed only 
using VLAN traffic tagged with the value specified in the Mgmt. VID field. Over-the-air 
management is possible only after creating a VLAN tagged group and VLAN tagged 
connections for each PTP Slave. 
It is recommended to create and test a VLAN group for tagged management traffic before 
activating the Mgmt Tag Enable function. Set the associated QoS and priority values to 
ensure management traffic has adequate priority and bandwidth during system operation. 
Mgmt. VID: Enter the VLAN ID. When Mgmt. Tag Enable is selected, the system 
recognizes only management commands with this VLAN ID. 
Important: The VLAN network support should be verified before enabling this feature 
to ensure the AN-80i system will be reachable using the VLAN tagged traffic.