instructions for future use.
inStALLAtion 
SteP 1.     With power off, wire this LRM-AS according to the diagram show.   caution!  Do not wire unit “live” 
(with power on the circuit) and do not allow the yellow wire to contact line voltage, neutral or ground 
or you will damage the device.    If more than one LRM-AS is to be installed in a wall box, scored tabs 
on the side can be broken off by bending back and forth with pliers, to accommodate proper fit. Apply 
power when completed. 
Proper Single Gang Installation
Using LRM-AS’s standard full heat-sink (all tabs), the connected incandescent lamp load shall not exceed 500W.
If a tab is removed from one side of the LRM-AS unit, the connected incandescent lamp load must not exceed 
400W.
If both tabs are removed from the LRM-AS unit, the connected incandescent lamp load must not exceed 300W.  
Proper Dual Gang Installation
The connected incandescent lamp load must not exceed 400W for each of the two LRM-AS units.  
Proper Triple Gang Installation
The connected incandescent lamp load must not exceed 300W for each of the three LRM-AS units. 
Air Gap Switch
The LRM-AS has an air gap switch on the face (lower left), that when pulled out, completely removes the power 
available to the load (simply turning the dimmer off does not).  This enables the lamps that are controlled by 
the device to be changed with minimal danger of electrical shock.  The air gap switch must be pushed all the 
way back in for the dimmer to operate the lamps again.
incLudinG LRM-AS to the netWoRk
SteP 1..   Prepare the Controller to include a unit to the network by adding it to a group (method of adding a 
node to the network).  Refer to controller instructions.  
SteP 2.    the LRM-AS must be in its permanently installed location.
  • To add a node: Tap the button.
  • To remove a node: Tap the button 3 times, then press and hold (Ex. tap, tap, tap, hold)
SteP 3.    You should see an indication on your Controller that the “DEvICE WAS INCLUDED” or “DEvICE 
WAS EXCLUDED” in the network. 
note:  if you have trouble adding the LRM-AS to a group it may be that the Home ID and Node ID were 
not cleared from it after testing.  You must first “RESET UNIT” with your controller to remove it from the 
network.  If using the EHC-100 select “SETUP” and scroll to “RESET UNIT” 
Although adding it to a group includes it in the network, removing it from a group does not remove it from the 
network.  If removed from a group, it functions only as a repeater.   
Basic OperaTiON
Local Control
The top or bottom of the LRM-AS switch can be used to carry out inclusion (add to a group), association, 
exclusion (remove from group) or reset (remove from network).    
Pushing the top or bottom of the switch, the LRM-AS allows the user to do the following:
•   Turn ON, OFF, DIM or bRIgHTEN the load attached.
•   To include or exclude the module, see step 2 above.
Once the device has been added, when a controller prompts you to “Send Node ID” or to “Press button on Unit”, 
quickly tap the top or bottom of the switch 3 times, then press and hold (Ex. tap, tap, tap, hold).  
•   Tapping top of the switch turns the load attached ON.
•   Tapping bottom of the switch turns the load attached OFF.
•    Pressing and holding the top of the switch will brighten the load attached, and pressing and holding the