Advanced Control Technologies Inc. 0810-01 Manuale Utente

Pagina di 5
Evolve LRM-1000, Series 300, Rel. 5.2 Instructions
P/D 101011
LRM-1000
by Evolve Guest Controls
2
INSTALLATION
 STEP 1..   With POWER OFF, wire this LRM-1000 according to the diagram shown.  Caution!  Do not wire unit “live”
(with power on the circuit).  Apply power when completed.
Proper Single Gang Installation
Using LRM-1000’s standard full heat-sink (all tabs), the connected incandescent lamp load shall not exceed 1000W.
If a tab is removed from one side of the LRM-1000 unit, the connected incandescent lamp load must not exceed
900W.
If both tabs are removed from the LRM-1000 unit, the connected incandescent lamp load must not exceed 800W.
Proper Dual Gang Installation
The connected incandescent lamp load must not exceed 900W for each of the two LRM-1000 units.
Proper Triple Gang Installation
The connected incandescent lamp load must not exceed 800W for each of the two LRM-1000 units.
Air Gap Switch
The LRM-1000 has an air gap switch on the face (lower left), that when pulled out, completely removes the power
available to the load (simply turning the dimmer off does not).  This enables the lamps that are controlled by the
device to be changed with minimal danger of electrical shock.  The air gap switch must be pushed back in for the
dimmer to operate the lamps again.
INCLUDING  LRM-1000 TO THE NETWORK
STEP 1.     Prepare the Controller to include a unit to the network by adding it to a group (method of adding a
node to the network).  Refer to controller instructions.
STEP 2.      The LRM-1000 must be in its permanently installed location to add a node:
Via Network Wide Inclusion (NWI):  Tap the switch once. This can be done upon power-up of the
node to be included, or once the controller is prepared to add all nodes to the network.
Via Classic Inclusion:   Tap the switch twice.
To remove a node:  Tap switch twice.
STEP 3.     You should see an indication on your Controller that the “DEVICE WAS INCLUDED” or “DEVICE
WAS EXCLUDED” in the network.
NOTE:  If you have trouble adding the LRM-1000 to a group it may be that the Home ID and Node ID
were not cleared from it after testing.  You must first “RESET UNIT” with your controller to remove it from the
network.  If the EHC-100 select “SETUP” and scroll to “RESET UNIT”
Although adding it to a group includes it in the network, removing it from a group does not remove it from the
network.  If removed from a group, it functions only as a repeater.
BASIC OPERATION
Local Control
Pushing the top or bottom of the switch, the LRM-1000 allows the user to do the following
 Tapping top of the switch turns the load attached ON.
 Tapping bottom of the switch turns the load attached OFF.
 Tapping and holding the top of the switch will brighten the load attached, and tapping and holding the bottom
of the switch will dim the load.