LED indication
The LED on the LRM-1000 will turn ON when the load attached is OFF to act as a night light.  However, the LED
can be user configured to turn ON when the load attached is ON, if so desired,
Remote Control
The LRM-1000 will respond to BASIC and MULTILEVEL commands that are part of the EvolveNet system.  Refer
to your controller’s instructions as to whether your controller can transmit those commands.
All On/All Off
The LRM-1000 supports the ALL ON/ ALL OFF commands.
The LRM-1000 can be set to respond to ALL ON and ALL OFF commands 4 different ways.
Refer to your controller for information on how to set the LRM-1000 to operate in the manner you desire. Some
controllers may be only able to set certain settings of ALL ON/ALL OFF response.
The 4 different ways the LRM-1000 can be setup to respond to ALL ON and ALL OFF commands are:
•  
LRM-1000 will not respond to ALL ON or the ALL OFF command.
•  
LRM-1000 will respond to ALL OFF command but will not respond to ALL ON command.
•  
LRM-1000 will respond to ALL ON command but will not respond to ALL OFF command.
•  
LRM-1000 will respond to ALL ON and the ALL OFF command (default).
Configuration
The LRM-1000 supports the Configuration command.
The LRM-1000 can be configured to operate slightly differently than how it works when you first install it. You can
use a EHC-100 to send Configuration commands, (Refer to the Setup Menu, Configuration section) and configure
the following:
Night Light
The LED on the LRM-1000 will by default, turn ON when the load attached is turned ON. To make the LED turn
ON when the load attached is turned OFF instead, set parameter 3 to a value of 1.
•   Parameter No: 3
•   Length: 1 Byte
•   Valid Values = 0 or 1 (default 0)
Invert Switch
To change the top of the switch to OFF and the bottom of the switch to ON, set parameter 4 to 1.
•   Parameter No: 4
•   Length: 1 Byte
•   Valid Values = 0 or 1 (default 0)
Each Configuration Parameter can be set to its default by setting the default bit in the Configuration Set command.
See your controller’s instructions on how to do this (and if it supports it).
All Configuration commands will be reset to their default state when the LRM-1000 is excluded from the EvolveNet
network by using the controller to reset the node (on the EHC-100 select “SETUP” and scroll to “RESET UNIT”).