4. 
The system will prompt for Repeater 1’s number. If no Repeaters are being used, press the Esc 
key. (skip step 5) Otherwise, enter the 7-digit serial number of the Repeater.  
5. 
The system will then prompt for Repeater 2’s number. Enter the 7-digit serial number of the 
second Repeater. If only one Repeater is being used, press the Esc key. 
6. 
The system refreshes the transceiver’s Call Book menu with the new changes. 
7. 
Press the Esc key to return to the Main Menu. 
Note:  When entering numbers into the Call Book, Repeaters need only be defined in the Master Call 
Book. The Slave Call Book only requires the Master’s Serial number. A repeater need not have 
anything listed in its Call Book. 
P
ROGRAMMING 
P
OINT
-
TO
-P
OINT 
E
XTENDED 
C
ALL 
B
OOK TO 
U
SE 
T
HREE OR 
F
OUR 
R
EPEATERS
 
In a Point-to-Point configuration FreeWave transceivers can utilize up to 4 Repeaters. To use 3 or 4 
Repeaters, program the Call Book with the Slave’s serial number, followed by the first 2 Repeaters. On 
the next line enter 999-9999 as the transceiver to call. When prompted for the Repeaters enter the third 
and fourth Repeaters in the link. 
The illustration below depicts a Point-to-Point link where a Slave is called through 4 Repeaters. In this 
example the Master is calling the Slave, 571-3872, through Repeater 1, 901-1234, then Repeater 2, 910-
0234, then Repeater 3, 571-3456, and finally Repeater 4, 571-4567. Entering of serial number 999-9999 
in line 1 instructs the Master to continue calling through the Repeaters programmed on that line. 
 
It is important that the Call Book slots (0-9) are filled sequentially starting with slot 0.   When a Master is 
instructed to Call All, it will call all Slaves listed until it reaches the first serial number of 000-0000. If a 
serial number is entered after the all zero number or as a Repeater, it will not be recognized as a valid 
number by the Master.