Commissioning
Chapter 3 - Commissioning
3.1
Configuring Basic Parameters of Base 
Station
3.1.1
NPU Parameters Required for Management
After completing the installation process, as described in the preceding chapter, 
some basic NPU parameters must be configured using the Monitor application via 
the MON port of the NPU. These parameters are necessary to enable remote 
management using SNMP or Telnet.
If the NPU is in the default factory configuration, or if the IP parameters of either 
the Data or Management port are known, you may configure the parameters using 
Telnet. You may also use AlvariCRAFT, provided you know the IP parameters of 
one port and the Authorized Managers list in the NPU is either empty (default) or 
includes the IP address of the AlvariCRAFT station.
 for information on how to access the Monitor application either 
via the MON port or via Telnet and how to use it.
Refer to the AlvariCRAFT User Manual for information on how to use it. 
The basic parameters are listed in 
 for detailed 
information on the applicable parameters.
NOTE
The default Installer password is "installer".
Table 3-1: Basic NPU Parameters
Management Option
Parameters
MGMT port
„
Management Port IP address
„
Management Port Subnet Mask
„
Management Port Gateway
„
Management Port Destination Subnet
„
Management Port Destination Subnet Mask
„
Management Port Management Traffic Enable/Disable