6 - 9
Data Format Required, Drop Prefix/Suffix
Scanned data is modified according to your data format.  If a data format is 
found for a particular symbol, those prefixes and suffixes are not 
transmitted.  Any data that does not match your data format requirements 
generates an error tone.  If you wish to process this type of bar code without 
generating an error tone, see 
.
Choose one of the following options.  
Default = Data Formatter On, Not 
Required, Keep Prefix/Suffix.
Data Format Non-Match Error Tone
When a bar code is encountered that doesn’t match your required data for-
mat, the scanner normally generates an error tone.  However, you may 
want to continue scanning bar codes without hearing the error tone.  If you 
scan the Data Format Non-Match Error Tone Off bar code, data that 
doesn’t conform to your data format is not transmitted, and no error tone 
will sound.  If you wish to hear the error tone when a non-matching bar 
code is found, scan the Data Format Non-Match Error Tone On bar code.  
Default = Data Format Non-Match Error Tone On.
* Data Formatter On,
Not Required, 
Keep Prefix/Suffix
Data Formatter On,
Not Required, 
Drop Prefix/Suffix
Data Format Required,
Keep Prefix/Suffix
Data Format Required,
Drop Prefix/Suffix
* Data Format Non-Match Error 
Tone On
Data Format Non-Match 
Error Tone Off
Preliminary Draft