To put the scanner in multiple scanner mode, scan the bar code below.  Once 
you scan this bar code, the scanner is unlinked from the base and must be 
placed into the base to re-link.
Scanner Name
You may assign a name to each scanner you are using.  When you have multi-
ple scanners linked to one base, you may want to name each scanner so you 
will be able to control the scanner receiving imaging commands sent from the 
base.
The default name for a Xenon is “Xenon.”  If you have more than one scanner 
linked to a base, and they all have the default names, the first scanner linked to 
the base receives commands.  You can change the name of a scanner using a 
serial command (refer to 
mand.  To change the name serially, unlink all except one of the scanners from 
the base.  Send “:Xenon:BT_NAM
name.”, where name is the new scanner 
name.  If you wish to change the names of additional scanners, re-link them one 
at a time and repeat the “:Xenon:BT_NAM
name.” command for each scanner.
Multiple Scanner Operation