Honeywell International Inc. VMSR Manuale Utente

Pagina di 4
 
3.  Installation 
3.1 
Installation Kit 
The installation kit consists of the following items to be used during 
the installation procedure: 
 
One mounting template 
 
Two pan head screws and wall plugs 
 
One L-shaped security screw tool 
 
One security screw 
3.2 
Mounting the AY-x20 Reader 
Before mounting, you should determine the best location for the 
reader. 
To mount the reader: 
1.  Peel off the back of the self-adhesive mounting label template and 
place it at the required mounting location. 
2.  Using the template as a guide, drill two holes (sizes indicated on 
the template) used for mounting the reader onto the surface. 
3.  Insert a suitable wall plug into each hole. 
4.  Drill a 10-mm (7/16”) hole for the cable. If mounting on metal, 
place a grommet or electrical tape around the edge of the hole. 
5.  Wire the reader to the controller as described in Section  4. A linear 
type power supply is recommended. 
6.  Remove the reader's snap-off front cover to reveal the two screw 
holes (see Figure 2 ). 
Figure 2: Removing the Top Cover 
 
7.  Align the two holes of the reader with those drilled in the wall and 
firmly attach the reader to the wall with two screws, whose size is 
indicated on the template. 
8.  Relocate the front cover onto the reader. 
 
The reader can also be mounted using strong epoxy glue. After 
application, the reader should be firmly held in place until the 
glue dries. 
 
 
Card readers are to be used with control panels whose power 
supply is UL Listed Class 2 or equivalent. 
4.  Wiring 
The AY-x20 is supplied with a 10-conductor 18” pigtail. 
To connect the reader to the controller: 
1.  Prepare the reader cable by cutting its jacket back about 3 cm 
(1¼") and strip the insulation from the wires about 1.2 cm (½"). 
2.  Prepare the controller cable by cutting its jacket back 3 cm (1¼") 
and strip the insulation from the wires about 1.2 cm (½"). 
3.  Splice the reader’s pigtail wires to the corresponding controller 
wires (as indicated in Table 1) and cover each joint with insulating 
tape. 
4.  If the tamper output is being utilized, connect the purple wire to 
the correct input on the controller. 
5.  Trim and cover all unused conductors. 
 
• 
The individual wires from the reader are color-coded according the 
Wiegand standard. 
• 
When using a separate power supply for the reader, this supply 
and that of the controller must have a common ground. 
• 
The reader’s cable shield wire should be preferably attached to an 
earth ground, or a signal ground connection at the panel, or 
power supply end of the cable. This configuration is best for 
shielding the reader cable from external interference. 
Table 1: Wiring 
Wire Color 
Wiegand 26-Bit Output 
Mode 
Clock & Data Output 
Mode 
Red 
+DC 
+DC 
Black 
Ground 
Ground 
Green 
Data 0 
Data 
White 
Data 1 
Clock 
Orange 
Green LED 
Green LED 
Brown 
Red LED 
Red LED 
Yellow 
Buzzer 
Buzzer 
Blue 
Hold 
Hold 
Purple 
Tamper 
Tamper 
Grey 
Open Input 
Connected to GND