Murata Electronics North America 2410G Manuale Utente
WIT2410
2000- 2005 Cirronet
Inc
37
M-2410-0000 Rev F
When the radio is linked to another radio, a communications test can be run by clicking
on the Transmit button or pressing the F6 key. Whatever ASCII string is in the Transmit
String window will be transmitted as shown below.
on the Transmit button or pressing the F6 key. Whatever ASCII string is in the Transmit
String window will be transmitted as shown below.
If the other radio is sending data, the received data will be displayed in the WinCOM
window.
window.
If the Binary box is checked, all characters received will be displayed subject to the
limitations of Windows. For example, a carriage return will not return the cursor to the
left side of the window but the character corresponding to
limitations of Windows. For example, a carriage return will not return the cursor to the
left side of the window but the character corresponding to
0xd
value of the carriage return
will be displayed. Similarly, if the Hex Mode box is checked, all characters are displayed
in hexadecimal format.
in hexadecimal format.
The Clear Screen button deletes all the text in the display window. The Clear CTS and
Clear DCD buttons reset the respective changes counters to zero.
Clear DCD buttons reset the respective changes counters to zero.