When the radio is linked to another radio, a communications test can be run by clicking
on the Transmit button or pressing the F6 key. Whatever ASCII string is in the Transmit
String window will be transmitted as shown below.
If the other radio is sending data, the received data will be displayed in the WinCOM
window.
If the Binary box is checked, all characters received will be displayed subject to the
limitations of Windows. For example, a carriage return will not return the cursor to the
left side of the window but the character corresponding to 
0xd
 value of the carriage return
will be displayed. Similarly, if the Hex Mode box is checked, all characters are displayed
in hexadecimal format.
The Clear Screen button deletes all the text in the display window. The Clear CTS and