COOPER INDUSTRIES INC FH1847N Manuale Utente

Pagina di 36
T245 Control System Manual
7
Function
Wire # 54-pin (32A10P)
M.S. Pin
Board References
Pole Guide/Platform OPEN
12
V
O3 (S20)
Pole Guide/Platform CLOSE
21
W
O4 (S20)
Digger Shift HIGH
27
X
O5 (S20)
Digger Shift LOW
4
Y
O6 (S20)
Auger LATCH
2
Z
D4 (R1300)
Auger UNLATCH
20
a
D5 (R1300)
Throttle UP
31
b
D6 (R1300)
Throttle DOWN
7
c
D7 (R1300)
Emergency Power
9
d
D3 (R1300)
Electronic Throttle Output (pulse-width
modulated signal; formerly 0 to 5V)
1
e
O9 (S20)
Hydraulic Tool Valve
43
f
D8 (R1300)
Upper Boom Extended Switch (N.O.
contact)
32
g
J2 pin 6 (R1300)
Intermediate Boom Retracted Switch
(N.O. contact)
28
h
J2 pin 7 (R1300)
Upper Boom Retracted Switch (N.O.
contact)
8
j
J2 pin 8 (R1300)
(not used)
k
Auger Overstow Switch (N.O. contact)
Input
33
m
J2 pin 2 (R1300)
(spare switch input)
15
n
J2 pin 3 (R1300)
(spare switch input)
17
p
J2 pin 4 (R1300)
Boom Stowed Switch (N.O. Contact)
Input
11
q
J2 pin 5 (R1300)
+5V Power for N.O. Switches
42
r
J2 pin 1 (R1300)
+5V for Proportional Pressure and
Angle Sensors
34
s
J3 pin 1 (R1300)
Angle Sensor Input
(-20.0° = 0.5V, +80.0° = 4.5V)
16
t
J3 pin 3 (R1300)