COOPER INDUSTRIES INC FH1848D Manuale Utente

Pagina di 31
18
7.3. T47 Cable Remote
If you have purchased the optional T47 Cable Remote, you may operate the
Digger Derrick Control System with all of the electronic safety features afforded with the
Radio Transmitter, but via a hardwire (cable).  To activate the T47 Cable Remote, release
the red Emergency Stop button and switch on the T47’s POWER switch—the control of
the machine is now taken away from the Radio Transmitter and given to the T47 Cable
Remote.  All control functions operate as in the T45 Transmitter.
Note that for safety, the Cable Remote’s Emergency Stop button must be released
even when operating from the Radio Transmitter; this allows someone to stop the
machine at the Cable Remote.
The numeric display in the T47 Cable Remote does not have any distance
limitation as in the T45.  The display will work as long as the T47’s cable is connected,
the T47’s POWER switch is turned on and the EMERGENCY STOP is released.
7.4. Emergency Override Panel
If you have not purchased the T47 Cable Remote, you must have an Emergency
Override Panel connected in place of the Cable Remote.  To operate from the Emergency
Override Panel, make sure the Emergency Stop button on the Panel is released and press
and hold the ENABLE button while operating the toggle switches on the Panel.