The transmitter’s Paddles control the receiver’s proportional output.  The Paddles/Joysticks are used in conjunction with 
any of the transmitter’s switches.  The proportional output can be activated when a switch is held UP or DOWN; it will be-
come active at an increasingly high level as the Paddle/Joystick is pushed/pulled.  The minimum and maximum levels of 
the proportional output can be calibrated by following these steps. 
Refer to the Light Legend below for diagram details. 
 
NOTE: Calibration settings can be reset to factory default in steps 3 & 4 by holding the [Power] switch UP or DOWN for 5 seconds
 
A. Refer to steps in “Power the 
Transmitter” 
B. Supply power to the R2160 
B. 
ESTOP  FAULT LINK STATUS 
 
 
 
1. Power T2300, Power R2160 
 
 
A. Hold [Power] switch DOWN 
for 5 seconds until the 
(Battery) LED goes to alter-
nating RED and YELLOW.  
B. Release [Power] switch  
2. Setup T2300 into Configuration 
3. Set Minimum Level 
 
 
A. Push the paddle (function) in the 
direction you wish to calibrate 
until the (Active) LED comes on 
B. Hold paddle and Press [Power] 
switch UP to increase minimum 
level or DOWN to decrease it 
4. Set Maximum Level 
 
 
A. Fully push the paddle (function) in 
the direction you wish to calibrate 
until the (E-Stop) LED comes on. 
B. Hold paddle and Press [Power] 
switch UP to increase maximum 
level or DOWN to decrease it 
5. Power Off 
A. Press [E-Stop]  
A. 
A. 
B. 
A. 
A. 
B. 
B. 
Note: 
Repeat steps 3 and 4 for each paddle (function) that needs to be calibrated.  
 
A. 
 Calibrating Proportional Controls