Tether connection detected 
 
Low battery.  Unit will run approximately 20 hours after Battery light starts flashing. 
 
Power switch is stuck in the “UP” position
.  
 
 
 
The Active light remain on momentarily when a function is activated (i.e. a switch or 
paddle is triggered).  This is normal operation. 
 
 
 
Normal Operation 
The transmitter is in Download Mode.
 
 
Normal Operation 
The Active light will flash 2 times per second, indicating that the transmitter is sending 
signals to the receiver.   
 
Stuck switch detected.  Ensure that all switches are in a centered position.  The trans-
mitter will not power up when a function is ON.
 
 
On Power Up 
Release the E-Stop button within 10 seconds to power up the transmitter, or the unit will 
power down. 
 
On Power Up 
Press and release the E-Stop button within 10 seconds to power up the transmitter, or 
the unit will power down.
 
 
The transmitter is in Calibration mode 
STOP 
STOP 
STOP 
STOP 
STOP 
STOP 
STOP 
STOP 
STOP 
STOP 
Light Legend  
Solid 
Slow  
Flash 
Fast  
Flash 
Red  
Light 
Green  
Light 
Alternating Red 
& Yellow Light 
Yellow 
Light 
 Diagnostics—T2300 Transmitter 
Status 
Module 1 
Module 2 
Module 3 
Module 4 
Module 5 
Module 6 
Module 7 
Status Indicator 
 
Module is operating properly 
 
Low battery condition detected 
 
There is a fault with the module 
 
Fuse blown 
 
Communication to the module is active 
 
 
STATUS 
 
STATUS 
 
STATUS 
STATUS 
STATUS 
 
Module is installed and operating properly 
 
There is a short to supply 
 
There is a short to ground / over current 
 
No Module installed 
Module 1-7 Indicators 
MODULE 
 
MODULE 
 
MODULE 
MODULE 
Indicator lights for the D180 Expansion Module 
 Diagnostics - D180 Expansion Module