Applied Concepts Inc ACMI006 Manuale Utente
Internal Circuit-Test
An internal circuit test can be performed at any time by pressing the
SELF TEST key. This performs a diagnostic check on the
display/counting unit, the selected antenna, and antenna cable. Since
only the selected antenna is tested, it is necessary to perform this test
twice -- once with the front antenna selected, and once with the rear
antenna selected.
SELF TEST key. This performs a diagnostic check on the
display/counting unit, the selected antenna, and antenna cable. Since
only the selected antenna is tested, it is necessary to perform this test
twice -- once with the front antenna selected, and once with the rear
antenna selected.
The display/counting unit will first complete a processor check,
memory check, and crystal accuracy check; followed by the display
of speeds of 10, 35, and 65 (Figures 37, 38, and 39); and ending with
a display of the display/counting unit internal operating temperature
in degrees Fahrenheit (e.g., 110
memory check, and crystal accuracy check; followed by the display
of speeds of 10, 35, and 65 (Figures 37, 38, and 39); and ending with
a display of the display/counting unit internal operating temperature
in degrees Fahrenheit (e.g., 110
°F) (if the unit has been ordered in
kilometers, the temperature will be displayed in Celsius (e.g., 35
°C)), and input battery voltage (e.g., bAt 13.8) (Fig 40 and Fig 41,
respectively).
°C)), and input battery voltage (e.g., bAt 13.8) (Fig 40 and Fig 41,
respectively).
A comprehensive test is also performed on the selected antenna by
the display/counting unit to ensure the integrity of the selected
antenna cable and antenna electronics. After all the tests are
completed, PASS (Fig 42) along with a 4-beep “happy” tone
indicate successful test completion. FAIL (Fig 43) along with a 15-
beep tone indicates a failed self-test.
the display/counting unit to ensure the integrity of the selected
antenna cable and antenna electronics. After all the tests are
completed, PASS (Fig 42) along with a 4-beep “happy” tone
indicate successful test completion. FAIL (Fig 43) along with a 15-
beep tone indicates a failed self-test.
Note: We recommend that the internal circuit test be performed on
each antenna.
each antenna.
S
XMIT FRONT REAR
SAME SLOW
FAST LOCK
TARGET
PATROL
Fig 37
S
XMIT FRONT REAR
SAME SLOW
FAST LOCK
TARGET
PATROL
Fig 38
S
XMIT FRONT REAR
SAME SLOW
FAST LOCK
TARGET
PATROL
Fig 39
S
XMIT FRONT REAR
SAME SLOW
FAST LOCK
TARGET
PATROL
Fig 40
S
XMIT FRONT REAR
SAME SLOW
FAST LOCK
TARGET
PATROL
Fig 41
S
XMIT FRONT REAR
SAME SLOW
FAST LOCK
TARGET
PATROL
Fig 42
S
XMIT FRONT REAR
SAME SLOW
FAST LOCK
TARGET
PATROL
Fig 43
Automatic Self-Test
An automatic self-test (indicated by a 4-beep “happy” tone) is performed every 10 minutes while S
PATROL
is transmitting.
Switching antenna will reset the 10 minute timer.
19