Pepperl + Fuchs Inc IUH-F117-V1 Manuale Utente

Pagina di 50
IUH-F117-V1-*
Product Description
 201
2-
09
11
Bank 00
The segment bank 00 contains the password manager, comprising the access 
password and the kill password. This range is not currently supported by IUH-
F117-V1-*.
Bank 01
In addition to the UII, the segment bank 01 contains a calculated checksum CRC 
(cyclic redundancy check) for verifying data on the tag and the protocol control 
(PC) range. The PC range contains:
The length of the UII
The characteristic of the Application Family Identifier (AFI) field
A bit switch that shows whether the UII contains an EPC or MITL number 
sequence in accordance with ISO (see chapter 4.1.6, see chapter 4.1.7& 
see chapter 7.3)
A bit switch that shows whether data is stored in segment bank 11 (if 
present)
All data in segment bank 01 are automatically set by IUH-F117-V1-*. The data is 
addressed via the commands single read special read-only code (SS), single 
write special read-only code (SP), enhanced read special read-only code (ES) 
and enhanced write special read-only code (EP). (see "Single Read Special 
Bank 10
Segment bank 10 contains the part number and the serial number of the tag. This 
data is permanently stored without being changed.
The data in segment bank 10 can be read out via the commands single read read-
only code (SF) and enhanced read read-only code (EF). (see "Single read fixcode 
Bank 11
Segment bank 11 contains an area to which the user has free access. Depending 
on chip type, this area has different sizes or is not present.
The data in segment bank 11 is addressed via the commands single read words 
(SR), single write words (SW), enhanced read words (ER) and enhanced write 
SW" on page 33, see "Enhanced Read Words ER" on page 33& see "Enhanced 
Write Words EW" on page 33)
4.1.6
Electronic product code EPC
The electronic product code is a unique code composed of a series of digits. This 
series of digits has a defined structure and a length of 64 bits, 80 bits, 96 bit or 
longer (depending on the EPC identification number used), is stored on the RFID 
transponder and uniquely identifies every transponder all over the world.