FLIR Commercial Systems Inc. MG300 Manuale Utente

Pagina di 20
16                                                   MG300-EN V2.0   4/11 
 
Specifications 
Function Range 
Resolution 
Accuracy 
DC Voltage 
 
400mV 0.01mV 
±(0.06% reading + 4 digits) 
4V 0.0001V 
40V 0.001V 
400V 0.01V 
1000V 0.1V 
±(0.1% reading + 5 digits) 
AC Voltage 
(AC+DC) 
50 to 1000Hz 
400mV 0.1mV 
±(1.0% reading + 7 digits) 
4V 0.001V 
40V 0.01V 
±(1.0% reading +5 digits) 
400V 0.1V 
1000V 1V 
All AC voltage ranges are specified from 5% of range to 100% of range 
DC Current 
400
μA 0.01μA 
±(1.0% reading + 3 digits) 
4000
μA 0.1μA 
40mA 0.001mA 
400mA 0.01mA 
10A 0.001A 
(20A: 30 sec max with reduced accuracy) 
AC Current 
(AC+DC) 
50 to 1000Hz 
400
μA 0.1μA 
±(1.5% reading +7 digits) 
4000
μA 1μA 
40mA 0.01mA 
400mA 0.1mA 
10A 0.01A 
(20A: 30 sec max with reduced accuracy) 
All AC voltage ranges are specified from 5% of range to 100% of range 
NOTE: Accuracy is stated at 65
o
F to 83
o
F (18
o
C to 28
o
C) and less than 75% RH.