Infrared Temperature Measurements 
1. 
Press the power 
 button to turn the meter on. 
2. 
Press the IRT button to enable the IR thermometer and the laser pointer. The laser pointer icon will 
flash while the mode is active. 
3. 
Press the up or down arrow button to change the temperature units 
4. 
Aim the laser pointer at the surface to be measured and read the surface temperature in the 
secondary display. 
5. 
Release the IRT button. The last temperature measured and the laser icon will remain on the 
display for approximately 10 seconds before returning to ambient temperature measurement. 
IRT MAX MIN display: 
The meter can be set to display only the maximum or minimum temperature measured during an IR scan. 
1. 
With the meter in the IR hold mode, press the MODE button. “MIN” will appear in the display. 
2. 
Press the IRT button to enable the IR thermometer. The meter will display the minimum 
temperature measured and will update only when a lower temperature is measured. 
3. 
Press the MODE button twice to enable the MAX mode and proceed as stated above for the 
maximum temperature. 
4. 
The MAX or MIN temperature is not stored when the function is exited. 
IR Field of View 
Ensure that the desired target is larger than the spot size. As the distance from an object increases, the 
spot size of the area measured by the meter becomes larger. The meter’s field of view ratio is 8:1, 
meaning that if the meter is 8 inches (cm) from the target, the diameter (spot) of the object under test 
must be at least 1 inch (cm). Refer below to the field of view diagram. 
 
 
 
 
 
 
 
 
 
 
WARNING: Do not directly view or direct the laser pointer at an eye. 
Low power visible lasers do 
not normally present a hazard, but may present some potential for hazard if viewed directly for 
extended periods of time. 
 
 
 
 
 
 
1” @ 8”
2” @ 16”
20mm @ 160mm
40mm @ 320mm