FLIR Commercial Systems Inc. MO297 Manuale Utente

Pagina di 8
MO290 V3.0 03/09 
Specifications 
Function Range 
Accuracy 
Pinless Moisture  
0 to 99.9 
Relative only 
Ext. Pin Moisture 
0 to 99.9 
Relative only 
Pinless Depth 
Up to 0.75” (19mm) 
0 to 10% 
± 3%RH 
11 to 90% 
± 2.5%RH 
RH Measurement 
91 to 100% 
± 3%RH 
Air Temperature 
-20 to 170°F (-29 to 77°C) 
± 3.6°F (2.0°C) 
-4 to 31
°F  
± 9°F 
32°F
 
 ± 
2°F 
33 to 392
°F Greater 
of 
±3.5% or ±9°F 
-20 to-1
°C 
± 4.5°C 
0
°C 
± 1°C 
IR Temp
 
1 to 200
°C 
Greater of ±3.5% or ± 4.5°C
 
Display 
3-digit primary display, 4-digit secondary display 
Vapor Pressure 
0 to 20.0kPA 
Dew Point 
-22 to 199°F (-30 to 100°C) 
Mixing Ratio 
0-999GPP (0 to 160g/kg) 
Sample Rate 
2 per second 
Backlight White 
LED 
Operating Temperature 
14 to 122°F (-10 to 50°C) 
Storage Temperature 
-14 to 140°F (-30 to 60°C) 
Operating Humidity 
90%, 32-86°F (0-30°C), 75%, 86-104°F (30-40°C),  
45%, 104-122°F (40-50°C) 
Storage Humidity 
90% 
Power Supply 
9V battery 
Battery Life 
6-8 weeks (4 hrs/day use), using alkaline batteries 
Auto Power Off (APO) 
After 30 minutes (nominal) inactivity. The APO function can be disabled by 
the user. 
APO Quiescent Current 
50µA maximum 
Dimensions 6.5x2.8x1.5’ 
(165x70x38mm) 
Weight 7.4oz 
(210g)