FLIR Commercial Systems Inc. RT30 Manuale Utente

Pagina di 20
  
RT30
™ Engineering Design Specification
 
 
Page 12 of 20
                  
5.2.2.1 Device 
Address 
The working address for all RT30 devices shall be 45583730
h
 (‘EX30’ ASCII). 
 
 
5.2.2.2 Supported 
Commands 
While the RT30 shall accept all commands defined in the Inter-Module RF Communications specification without 
system failure, the TU shall only send, and the RU shall only act upon, the following commands: 
 
• Alarm 
Status 
• Hello 
• Beep 
Code 
• Comm 
Channel 
Change 
 
 
5.3 S
WITCHES
 
5.3.1 
TU Power/Mode Switch 
This switch has three positions: 
 
•  Off – The unit is off, and battery power is completely disabled. 
•  NCV – The internal NCV circuit is enabled.  This setting can be overridden by attaching the External 
Probe. 
•  Light – The LDR circuit is enabled.  This setting can also be overridden by attaching the External 
Probe. 
 
 
5.3.2 
TU Calibrate/Channel Switch 
This switch is a momentary switch.  It has two functions: 
 
•  Calibrate – If the switch is pressed for more than 100mS, but less than 5 seconds, the RT30 shall enter 
Calibrate Mode.  A ‘short’ press is also used to select channels. 
•  Channel  – If the switch is pressed for more than 10 seconds, the RT30 shall enter Channel Select 
mode. 
 
 
5.3.3 
RU Power/Mode Switch 
This switch has three positions: 
 
•  Off – The unit is off, and battery power is completely disabled. 
•  On – The receiver is on, and the Beeper is enabled. 
•  Silent – The receiver is on, but the Beeper is disabled from announcing alarm conditions.  Beep codes 
for auxiliary functions shall still be sent. 
 
 
 
Confidential and Proprietary, Extech Instruments