FLIR Commercial Systems Inc. RT30 Manuale Utente

Pagina di 20
  
RT30
™ Engineering Design Specification
 
 
Page 13 of 20
                  
5.4 I
NDICATORS
 
5.4.1 TU 
Indicators 
The TU has two LED indicators: 
 
•  Power LED (Green) – This indicator shows that the TU is operating, and has battery power. 
•  Detect LED (Amber) – This indicator shows that the TU has detected voltage (when in NCV or External 
Mode) or a light level change (when in Light Mode). 
 
 
5.4.2 
Auxiliary TU Indications 
•  Startup – During initial power-up, the TU shall test the communications between the MCU and the RF 
System.  If successful, the Detect LED shall briefly light and then go out. 
•  EEPROM Init – If the EEPROM memory is corrupt or not yet programmed, the MCU shall re-program 
the data and clear all unused locations.  During this process, the Detect LED shall briefly flicker at a > 
5Hz rate.  Under normal circumstances, this indication shall only occur after the MCU is programmed. 
•  Channel Select – The Detect LED shall flash at a 2Hz rate. 
 
 
5.4.3 RU 
Indicators 
The RU has three LED indicators: 
 
•  Power LED (Green) – This indicator shows that the RU is operating, and has battery power. 
•  Detect LED (Amber) – When a wireless connection is present, this indicator is a mirror image of the 
TU’s Detect LED.  It shows that the TU has detected voltage (when in NCV or External Mode) or a light 
level change (when in Light Mode). 
•  Communication LED (Yellow) – This indicator shows that the TU and RU are in communication. 
 
 
5.4.4 
Auxiliary TU Indications 
•  Startup – During initial power-up, the RU shall test the communications between the MCU and the RF 
System.  If successful, the Detect and Communication LEDs shall briefly light and then go out. 
•  EEPROM Init – If the EEPROM memory is corrupt or not yet programmed, the MCU shall re-program 
the data and clear all unused locations.  During this process, the Detect and Communication LEDs shall 
briefly flicker at a > 5Hz rate.  Under normal circumstances, this indication shall only occur after the 
MCU is programmed. 
 
 
Confidential and Proprietary, Extech Instruments