FLIR Commercial Systems Inc. RT30 Manuale Utente
RT30
™ Engineering Design Specification
Page 17 of 20
7.0 EXTERNAL
CONNECTORS
7.1 E
XTERNAL
P
ROBE
C
ONNECTOR
The External Probe Connector shall be a standard RJ45-8 unshielded connector, without indicators.
Pin #
Signal Name
Direction
Description
1 GND
-
Signal
Ground
2
EXPDET
In
External Probe Detect
3
EXPINB
In
External Probe Input
4 ICPVPPB
In Programming
Vpp
5 ICPDATB
I/O Programming
Data
6 ICPCLKB
In Programming
Clock
7
EXTALGB
In
External Analog Input
(1)
8 GND
-
Signal
Ground
Notes: 1.
Future
expansion.
Figure 7 – External Probe Connector
8.0 MISCELLANEOUS
SPECIFICATIONS
8.1 D
ROP
T
EST
The RT30 shall be capable of withstanding a 1.5m drop, per ISTA #2a. The test includes one drop onto the
weakest corner, one drop onto each edge radiating from that corner, and one drop on each face of the meter, all
onto a flat, rigid base such as steel or concrete.
weakest corner, one drop onto each edge radiating from that corner, and one drop on each face of the meter, all
onto a flat, rigid base such as steel or concrete.
8.2 R
ESISTANCE TO
C
ONTAMINATION
Both the TU and RU shall be protected to the IP43 standards (protected against solid objects > 1mm
3
, direct
sprays of water ± 60° from vertical).