Deister Electronic GmbH MODEL260 Manuale Utente
GE Contactless Medium Read-Range Reader Model 260
21
Note: the 8RP Reader appears to the Microcontroller as four 2RP
boards.
boards.
Table 5: 8RP Reader Technology and Format
Reader Technology and
Format
SW1-1
SW1-2
SW1-3
SW1-4
Supervised F/2F
ON
OFF
ON
OFF
Table 6: 8RP Board Address Settings
Board Type
SW 1
5
6
7
8
Standard
ON
ON
ON
OFF
Board 1
a
a. Readers 1 - 8.
Does not apply.
OFF
ON
Board 2
b
b. Readers 9 - 16.
OFF
ON
Board Type
SW 2
1
2
3
4
5
6
7
8
Standard
OFF
OFF
ON
ON
ON
OFF
ON
OFF
Board 1
a
a. Readers 1 - 8.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Board 2
b
b. Readers 9 - 16
ON
ON
OFF
OFF
OFF
ON
OFF
ON