Troubleshooting
If the operation of a component is in doubt, substitute a known-good 
component and retry the system. Always verify wiring against the 
provided wiring information before powering up the reader.
 Table 7: Error Conditions and Possible Solutions
Condition
Possible Solutions
None of the 
LEDs are on. 
Present a known-good ISO 15693 or ISO 14443A 
type card to the reader while listening for the 
beeper. If the beeper sounds, the reader is faulty 
and should be replaced. If the beeper does not 
sound, check the following:
Power connections to the reader
Reader supply voltage at connector JP1 pin 3 
and that the ground connection JP1 pin 2 is 
secure
The green LED is 
always on. The 
green LED indi-
cates that the 
door strike is 
open. It is con-
trolled by the 
input on connec-
tor JP1 pin 7. 
Disconnect the wire on JP1 pin 7. If the green LED 
stays on, the reader is faulty and should be 
replaced. If the green LED goes off, then the prob-
lem is most likely not in the reader.
Reconnect the wire on JP1 pin 7 and measure the 
voltage at JP1 pin 7. A low voltage (0 to 2 VDC) 
turns on the green LED. If the voltage is low, there 
are two possibilities:
A short to ground in the wiring between the 
reader and microcontroller, or
The host system may be energizing the door 
strike
The door does 
not open and the 
green LED does 
not light when an 
ISO 15693 or 
ISO 14443A card 
is presented.
Verify that the door strike and the green LED are 
wired correctly.
Verify that the access card has been entered and 
that the reader has been properly configured in 
the host system.