Chamberlain Wireless Products Inc. CWA2000 Manuale Utente

Pagina di 4
 
© 2008, The Chamberlain Group Inc.
114A3896 
All Rights Reserved
FOR TECHNICAL SUPPORT DIAL OUR TOLL FREE NUMBER: 
1-800-528-9131
www.chamberlain-DIY.com
NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or modifications of this 
receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. 
THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following 
two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undesired operation.
The PIR Motion Sensor lights up, but the Base 
Station does not respond.
The PIR Motion Sensor must be programmed to Base 
Station (See Step 6). 
Ensure Base Station is on and is not muted.
If the green power light is not lit or is flashing, press 
the Mute Button on the top of the Base Station to wake 
it up.
If the green power is illuminated, look at the two small 
white Base Station switches next to the Learn Button. 
The #1 Dip Switch should be down, towards the circuit 
board. If it is up, the Base Station has been muted. If the 
Base Station signals when you press the Learn Button, 
it is not muted.
The Alert is not getting expected transmission 
range.
Keep both antennas vertical and keep PIR Motion 
Sensor antenna away from trees and metal objects. 
Ensure Base Station is in clearest possible sight of the 
PIR Motion Sensor. The less objects between the 
devices, the longer the range.
PIR Motion Sensor is detecting motion only part of 
the time.
To detect cars, it is best to mount PIR Motion Sensor at 
height of car’s motor and have it between ten and 
twenty feet from the road. Swivel sensor as needed.
Troubleshooting
The Alert is giving false alarms.
Check for moving tree branches or insects in sensor 
window. PIR sensor can also be triggered by light 
shining directly in sensor window, such as reflected 
sunlight, or motion in front of a light source.
It is possible that condensation has built up on the 
sensor. Wipe condensation from PIR Motion Sensor with 
cotton swab. Let it sit inside for a few hours, open to the 
air, without the batteries and it should correct itself.
Check Sensor Switches on PIR Motion Sensor. See 
Switch Settings.
Base Station beeps every ten minutes.
The battery in the Base Station is low. Replace with 
4 AA batteries or operate it using AC Adapter.
NOTE: Output switching capacity is low voltage 
(24V max, ac or dc).
NOTE: The manufacturer is not responsible for any radio 
or TV interference caused by unauthorized modifications 
to this equipment. Changes or modifications not 
expressly approved by the manufacturer could void the 
user’s authority to operate the equipment
.