Chamberlain Wireless Products Inc. OWK5 Manuale Utente

Pagina di 22
           2.3       INSTALLING THE GATE CONTROL UNIT (GCU)
Using Additional Contact / Clearance Sensors
- 4 -
- 13 -
           3.0    ACTIVATING A GATE CONTROL UNIT (GCU)
Open/Closed Contact Sensors  Dipswitch #3  Dipswitch#7  Dipswitch#8 
No contact sensors used  
OFF 
OFF 
OFF 
“Closed”  limit  switch  wired  to 
terminals #3 and #4 
ON 
OFF 
OFF 
“Open”  limit  switch  wired  to 
terminals   #3 and #4 
ON 
ON 
OFF 
Additional 
“Closed” 
limit 
switch  or  sensor  wired  to 
terminals #3 and #4 
ON 
OFF 
ON 
Additional 
“Opened” 
limit 
switch  or  sensor  wired  to 
terminals #3 and #4 
ON 
ON 
ON 
 
Mount  the  Oracle  Gate  Controller  near  your  Automatic  Gate 
Opener’s  control  panel  or  motor.    Most  gate  motors  have  simple 
relay  connections  (often  labeled  COMMON  and  CYCLE)  that 
connect  to  the  two  large  OPEN/CLOSE  relay  outputs  on  the Oracle 
Gate Controller. 
 
Note:  For  more detailed  installation  information, refer to Appendix A 
on pg. 15.
 
When you  are  ready to activate  the  GCU,  press the LEARN button 
on the GCU (see page 4 for location of the LEARN button), for one 
second.  The LED will light up solid for up to 20 seconds. 
 
Within 20 seconds, on the GAP, 
Enter your Master PIN Number (for example): 
 
Followed by the Gate Controller’s Identity:  
 
The  GAP  will  give  a  double-beep  and  the  GCU  LED  will  blink  3 
short blinks to indicate a successful activation.   
 
Note: If the GAP sounds a 4-beep error tone or the GCU gives 3 
double  blinks,  then  check  the  FAQ  section  for  the  possible 
solution.
  
 
If you only have one GCU then you are finished and can proceed to 
the  next  step.  For  additional  GCU’s,  repeat  the  process  until  all 
GCU’s have been successfully activated. 
 
Note:  You  can  now  assemble  the  GCU  by  snapping  the 
box/shell back onto the unit.
 
(1 - 4)
Selecting Gate Controller “ON” Time 
For  most  connections  to  an  Automatic  Gate  Opener,  the  default  setting  of  ½ 
second  is  best.    However,  for  connection  to  yard  lights,  cameras,  etc.,  you  may 
wish to adjust how long the connected device stays on.
 
Gate Controller 
“ON” Time 
Dipswitch 
#3 
Dipswitch 
#4 
½ second –  
No Limit Switch  
OFF 
OFF 
½ second –  
Using a Limit Switch 
ON 
OFF 
10 seconds 
OFF 
ON 
30 seconds 
ON 
ON 
 
NOTE:
 
For most gate system wiring, dipswitch #4 should be left “OFF.”  If you wire your gate 
controller to a limit switch, dipswitch #3 should be turned “ON”.
 
Enabling the Auto-Close Feature 
By  enabling  the  Auto-Close  feature,  the  Gate  Controller  will  attempt  to  close  the 
gate  45  seconds  after  it  is  opened.    This  feature  will  work  better  if  your 
configuration has at least one of the following elements: 
 
Separate Open / Close Terminals, 
A “Gate Closed” Sensor or limit switch, or 
A “Gate Open” Sensor or limit switch 
 
Otherwise,  the  Gate  Controller  must  assume  that  the  gate  has  not  opened  or 
closed for any other device.
 
Auto-Close Feature 
Dipswitch #6 
OFF (disabled) 
OFF 
ON (enabled) 
ON 
 
Warning:  Please remember safety!   Do not enable auto-close where  it might 
pose a risk of entrapment, causing injury, death, or damage to vehicles.
 
NOTE:  To  power  an  additional  contact  sensor  that  is  NOT  already  connected  to  your  gate  system,  short 
terminal #3 to ground, connects the switch across terminals 3 and 4, and turn dipswitch #8 ON.   
1 2 3 4
Model OWK
9/6/2007
Patents Pending