          2.1                INSTALLING THE BATTERIES
          2.2     SETTING THE GATE CONTROLLER IDENTITY
GATE CONTROL UNIT (GCU) INSTALLATION
- 14 -
- 3 -
Note:         Is a ‘Cancel’ button to cancel any call or key sequence.
 
Note:
  To  set  the  identity  of 
GCU  #2,  you  would  position 
the 
dipswitches 
as 
seen 
below. 
You can use up to 4 GCU’s with each OWK utilized.  If you use more than 
1  GCU,  the  additional  units  must  have  their  identity  set.  Changing 
dipswitches  #1  &  #2  on  the  Gate  Control  Unit  sets  the  Gate  Controller 
Identity.  (See below.) 
Open  the  GCU  by  holding  the  box/shell  portion  of  the  unit.    Then,  while 
tilting  the  bottom  section  (where  the  wire  is  located), pull the box/shell  off.  
Insert 4 ‘AA’ batteries into the exposed battery holder. 
 
Note: If used in locations that will be below -10°C (20°F), Lithium batteries 
are recommended. 
 
Note: Leave the box/shell off until after activation is complete.
 
Dipswitch Block
Learn Button
Terminal
Sample Configuration 1:  
Open Gate Only 
 
Use this configuration when you wish to use the Reporter Gate System as 
an  open-only  system,  which  automatically  closes,  based  on  a  timer  or  a 
magnetic loop. 
 
Enable the Auto-close feature on your Automatic Gate Opener. Connect the 
Reporter  Gate  Controller  as  shown  in  the  Basic  Gate  Controller 
Installation
 diagram.  Please refer to your product-specific manual for wiring 
information.  On  the  Reporter  Intercom,  disable  gate  status  checking  (as 
described above).
 
Sample Configuration 2:  
Wiring to separate OPEN and CLOSE terminals 
 
Use  this  configuration  when  you  wish  to  use  the  Reporter  Gate  System  to 
open  and  close  your  gate  and  check  the  gate’s  last  known  status,  without 
connecting to a limit switch or external gate status indicator.  
 
Disable the Auto-close feature on your Automatic Gate Opener. 
 
Connect Contact 2 to Ground, COM, or (-) on your Automatic Gate Opener. 
 
Connect Reporter Gate Controller Contacts 7 and 8 to “Strike Open”, “Open 
Only”,  “Remote”  or  a  similarly  named  contact  pair  on  your  Automatic Gate 
Opener.  Please refer to your product-specific manual for wiring information. 
 
If  your  Automatic  Gate  Opener  has  a  “Close”  or  “Close  Only”  contact  pair 
(e.g.  connecting  like  a  3-button  station),  connect  Contacts  5  and  6  to  the 
“Close” contacts. 
 
Slide Gate Controller Dipswitch #5 to the UP position. 
 
If  desired,  enable  Auto-close  on  the  Gate  Controller  by  flipping  Gate 
Controller Dipswitch #6 to the UP position. 
 
 
LED
Model OWK