After 2ms Guard Time the answer should be received on the User Port otherwise an error is
returned.
returned.
Table 10 - Receiving Serial Data Frame
Receive
Frame
Frame
Description
Low Start
bit
Error Bit
If set, an error was detected.
Data Bit 6
State of the User Port Bit 6
Data Bit 5
State of the User Port Bit 5
Data Bit 4
State of the User Port Bit 4
Data Bit 3
State of the User Port Bit 3
Data Bit 2
State of the User Port Bit 2
Data Bit 1
State of the User Port Bit 1
Data Bit 0
State of the User Port Bit 0
Parity Bit
Even Parity Bit
High Stop
Bit
If the Error bit is set or the Parity Bit is not correct, the Write User Port command returns an error
code.
code.
2.3.1.22 Quiet
This command sets a selected tag into halt state. Only ISO14443 A+B and SR176 tags are
supported.
supported.
Command
Command
Data
'q' None
Answer
Answer
Description
'Q'
Halt state successfully set.
'N'
Error: No Tag in the field [addressed tag not present or not responding]
2.3.1.22.1 ISO 14443 Type A
With ISO14443-3 Type A tags, the Quiet command always answers with 'Q' because the halt
command does not send any acknowledge.
command does not send any acknowledge.
In Part 4 a 'Deselect' command will be performed.
2.3.1.22.2 ISO 14443 Type B
Some ISO14443 Type B tags do not support this command or do not respond. ‘Quiet’ is an ISO
14443-4 command, so it will work only if the ‘Deselect’ command is supported by the
corresponding transponder.
14443-4 command, so it will work only if the ‘Deselect’ command is supported by the
corresponding transponder.
2.3.1.22.3 SR176
With SR176 tags the Quiet command always answer with 'Q' because the completion command
does not send any acknowledge.
does not send any acknowledge.