2.3.7   ‘e’ command – SAM data frame transfer 
This command sends a custom data block to a SAM.  Refer to ISO/IEC 7816 for more detail. 
Note: The SAM interface hardware does not support error repetition and does not check the parity 
bit.  Inverse convention cards are also not supported.  T=0 is not supported for non-ISO standard 
speeds. 
There are two versions of this command.  A flag bit in the option byte defines the command 
version.  Version 1 is the earlier one, now deprecated.  Version 2 now supports ISO/IEC 7816 
timeouts (BWT, CWT, WWT) both manual and automatic, TPDU interface for T=0, T=1 and a full 
frame length with buffer mechanism 
‘e’ command 
Command 
Data 
'e' 
Version 1: 
Downlink length (1 byte) 
Option byte (1 byte) 
Time-out (1 byte) 
Transmission factor byte (1 byte) 
Data (n bytes) 
 
Version 2: 
Downlink length LSB (1 byte) 
Option byte (1 byte) 
Downlink length MSB (1 byte) 
Time-out (1 byte) 
Transmission factor byte (1 byte) 
Return length 
Data (n bytes) 
Answer – Version 1 
Answer 
Description 
Data SAM 
response 
'P' 
End of communication 
'C' 
Error: CRC error 
'F' 
Error: General failure or incorrect ATR 
'N' 
Error: No SAM detected 
Answer – Version 2 
Answer 
Description 
Error Code 
00h – no error 
01h – error 
02h – wrong parameter 
Length 
Data length (2bytes): optional, depends on command code used 
Data SAM 
response 
 
August 2010 
 
Page 97 of 144 
© 2005-2010 HID Global Corporation.  All rights reserved.