HID Global Corporation 5553 Manuale Utente

Pagina di 144
 
HF Multi ISO RFID Reader User Manual, Firmware V1.4 
 
1508-USM-00-0-04 
2.3.7.3 
Option Byte Version 2 
Table 12 - Version 2 (Option Byte) 
Bit 
Description 
 
0 - 3 
Command code 
0h – Transaction 
1h – Activation 
2h – Deactivation 
3h – Warm reset 
6h – Cold reset 
9h – T1 S(WTX) multiplier 
Fh – T=1 Transaction 
 
all other values are RFU and should not be used 
 
4,5 
Protocol 
0h – T=0 transmit 
1h – T=1 
2h – raw mode 
3h – T=0 receive 
6 Manual 
timeouts 
1h – Version 2 
 
Command code – bits 0-3 
0h Transaction 
This command starts a transaction with the SAM and returns the received data. 
Timeout and return length depends on used protocol type and option byte. 
 
1h Activation 
This command activates the SAM and returns an ATR. If an error occurs, the SAM is 
automatically deactivated. 
Timeout, transmission factor and return length are not used. 
 
2h Deactivation 
This command deactivates the SAM. Do not remove the SAM until this command is sent. 
Timeout, transmission factor and return length is not used. 
 
3h Warm reset 
This command makes a warm reset and returns an ATR. If an error occurs, the SAM is 
automatically deactivated. 
Timeout, transmission factor and return length is not used. 
August 2010 
 
Page 99 of 144 
© 2005-2010 HID Global Corporation.  All rights reserved.