HID Global Corporation 0006A Manuale Utente
_____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page, E-mail - www.hidcorp.com - ProxPoint Installation Manual 6005-910 Rev A
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page, E-mail - www.hidcorp.com - ProxPoint Installation Manual 6005-910 Rev A
2 of 2
PARTS LIST (Included)
Quantity
Quantity
- ProxPoint
TM
Reader with snap-on cover and 18” cable
1
- #4-24 x 1” self-tapping flathead screw
2
- Installation manual
1
PARTS LIST (Not-Included)
Quantity
Quantity
- Wire splice
9
- DC Power supply 5.0 VDC or 12 VDC
2
Mounting Instructions
•
Determine an appropriate mounting location. The
reader may be mounted to any surface, including
metal.
metal.
•
Drill two (2) 5/64-inch (2mm) holes approximately 1
inch deep for mounting the reader.
•
Drill a 5/8-inch (16mm) hole for the cable.
•
Remove the snap-on cover from the reader and
secure the reader to the mounting surface.
•
Route the cable from the reader and/or power
supply to the host. A linear type power supply is
recommended. Check all electrical codes for proper
cable installation.
recommended. Check all electrical codes for proper
cable installation.
•
Test the operation of the reader. After completion of
the test, replace the snap-on cover.
Connecting the Reader to the Host
Connect the reader to the host according to the wiring
table below and the host installation guide.
table below and the host installation guide.
Wiegand
Clock & Data
Wire Color
+DC
+DC
+DC
Red
Ground
Ground
Ground
Black
---
Card Present
Violet
Data0
Data
Green
Data1
Clock
White
White
Shield Ground
Shield Ground
Shield Ground
Drain
Green LED
Green LED
Green LED
Orange
Red LED
Red LED
Red LED
Brown
Beeper
Beeper
Beeper
Yellow
Hold
Hold
Hold
Blue
Testing and Operation