HID Global Corporation 0006A Manuale Utente

Pagina di 4
_____________________________________________________________________________________________________
HID Corporation  9292 Jeronimo Road   Irvine, CA 92618-1905 USA TEL (949) 598-1600  (800) 237-7769  FAX (949) 598-1690
Web page, E-mail - www.hidcorp.com - ProxPoint Installation Manual 6005-910 Rev A
               3 of 2
  When power is applied to the reader the LED will
flash green three (3) times while the beeper beeps
simultaneously. The LED will then turn red. This
indicates that the microcontroller is operating
properly.
  Present an ID card to the reader. The LED will
momentarily turn green while the beeper beeps
once, indicating that the card was read successfully.
Important Product Specifications
Power requirements (linear supply)
Operating Voltage Range            5.0 – 16.0 VDC
Absolute Maximum Voltage        18 VDC
Peak Current                               80 Ma
Average Current 5V or 12V         20 Ma
Maximum cable distance             500 ft (153 m)
To host
FCC Compliance Statement: This device complies
with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must
accept any interference received, including interference
that may cause undesired operation.