HID Global Corporation 535Y Manuale Utente

Pagina di 11
_____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (714) 598-1600  (800) 237-7769  FAX (714) 598-1690
Web page, E-mail - www.hidcorp.com - ProxPro Plus Wiegand Reader Installation Manual 6030-900 REV G              9 of 10
Wall Mount Installationarts List
1) 
ProxPro Plus Reader, Rear Cable Exit
qty 1 ea (included)
2) 
This Installation Manual
qty 1 ea (included)
3) 
Screw, self tapping, 6-32 x 1.00, pan head
qty 2 ea (included)
4) 
Screw, machine, 8-32 x .875, flat head 82
°
, black
qty 4 ea (included)
5) 
Nut, clinch, black
qty 4 ea (included)
6) 
5 conductor Alpha 1295 C or equivalent. See cable notes.
User supplied
 
As required, up to 500’
7) 
Power Supply Requirements
User supplied
        Linear, 10-28.5VDC, 120mA
When using a gang box:
" Drill 
.188 hole in the 2 locations shown in figure 5.
"  Insert the 6-32 clinch nuts 4 places in back.
"  Mount reader to gang box using 6-32 self tapping screws.
"  Return cover using 8-32 machine screws. Ensure that the LED lens on the cover is lined up with the LED.
"  Apply “HID” label such that it is right side up.
When not using a gang box:
"  Return cover to base using screws provided with reader.  Ensure that the LED lens on the cover is lined up
with the LED.
"  Mount reader to wall using the 4 corner holes in the case.
"  Apply the “HID” label such that it is right side up.
FIGURE 5