Radio Frequency Interference
Motors and electronic devices generate RF noise that may interfere with the reception of the signal from a access
card. The effect of RF noise is typically a reduction of read range.  The Glass Mount ProxPro is susceptible to RF
interference as are all devices that receive RF signals.  Examples are radios, televisions, and cellular phones.  The
read range is affected by the amount of interference (noise) in the area.  The Glass Mount ProxPro should not be
mounted within ten feet of any monitors (VDTs or CRTs) because the scan frequencies of most monitors include
frequencies that may interfere with the signal received from the access control cards.
Product Specifications
Read Distance
Overall Operating Limits (12VDC - minimum)
8.5 inches (21.6 cm)
Non-Metallic Mounting (12VDC - typical)
9.5 inches (37.4 cm)
Mounted on Metal (12VDC - typical)
6.0 inches (15.2 cm)
Overall Operating Limits (24VDC - minimum)
9.0 inches (6.3 cm)
Non-Metallic Mounting (24VDC - typical)
10.5 inches (22.9 cm)
Mounted on Metal (24VDC -  typical)
7.0 inches (17.8 cm)
Environmental Characteristics
Designed for listing under UL 294 “Standard for Access Control System Units”
Operating Temperature Range
-30
o
C to 65
o
C (-22
o
F to 150
o
F)
Storage Temperature Range
-40
o
C to 85
o
C (-40
o
F to 185
o
F)
Operating Humidity Range
5% to 95% non-condensing
Operating Vibration Limit
.04 g2/Hz 20-2000Hz
Operating Shock Limit
30g, 11mS, Half Sine
Enclosure Material
UL Recognized Polycarbonate
Weight
13oz (364gms)
Power Requirements
Power supply
Linear type recommended
Operating Voltage Range
10VDC -28.5VDC
Maximum Average Current 5V/12V
150mA
Transient Protection (all terminals)
UL294
Reverse Voltage Protection
YES
Input Voltage (maximum data-0/1 lines)
28.5VDC
Input Voltage (maximum interface lines)
28.5VDC
Operating Parameters
Excitation Frequency
125KHz
Duty Cycle (alternate power level rate)
20% @ 60mS period
Read and Report Speed (26 bit Wiegand Card)
175mS
Maximum Cable Distance to Host
500 feet (152 meters)
LED Type                                                                 Bi-colored Red/Green
LED Operation (host control of red/green)
<.5V on LED control line
Beeper Operation (host control)
<.5V on beeper line
LED Control (default)
internal/single
Beeper Control (default)
Beeper enabled
Anti-Pass Back Delay (default)
1 second
Wiegand Data Pulse Widths (default)
40uS
Wiegand Data Interval (default)
2mS
Note: The above are recommended installation procedures. All local, state and national electrical
codes have precedence