HID Global Corporation 535Y Manuale Utente
_____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (714) 598-1600 (800) 237-7769 FAX (714) 598-1690
Web page, E-mail - www.hidcorp.com - ProxPro Plus Wiegand Reader Installation Manual 6030-900 REV G 10 of 10
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (714) 598-1600 (800) 237-7769 FAX (714) 598-1690
Web page, E-mail - www.hidcorp.com - ProxPro Plus Wiegand Reader Installation Manual 6030-900 REV G 10 of 10
Radio Frequency Interference
Motors and electronic devices generate RF noise that may interfere with the reception of the signal from a access
card. The effect of RF noise is typically a reduction of read range. The Glass Mount ProxPro is susceptible to RF
interference as are all devices that receive RF signals. Examples are radios, televisions, and cellular phones. The
read range is affected by the amount of interference (noise) in the area. The Glass Mount ProxPro should not be
mounted within ten feet of any monitors (VDTs or CRTs) because the scan frequencies of most monitors include
frequencies that may interfere with the signal received from the access control cards.
card. The effect of RF noise is typically a reduction of read range. The Glass Mount ProxPro is susceptible to RF
interference as are all devices that receive RF signals. Examples are radios, televisions, and cellular phones. The
read range is affected by the amount of interference (noise) in the area. The Glass Mount ProxPro should not be
mounted within ten feet of any monitors (VDTs or CRTs) because the scan frequencies of most monitors include
frequencies that may interfere with the signal received from the access control cards.
Product Specifications
Read Distance
!
Overall Operating Limits (12VDC - minimum)
8.5 inches (21.6 cm)
!
Non-Metallic Mounting (12VDC - typical)
9.5 inches (37.4 cm)
!
Mounted on Metal (12VDC - typical)
6.0 inches (15.2 cm)
!
Overall Operating Limits (24VDC - minimum)
9.0 inches (6.3 cm)
!
Non-Metallic Mounting (24VDC - typical)
10.5 inches (22.9 cm)
!
Mounted on Metal (24VDC - typical)
7.0 inches (17.8 cm)
Environmental Characteristics
!
Designed for listing under UL 294 “Standard for Access Control System Units”
!
Operating Temperature Range
-30
o
C to 65
o
C (-22
o
F to 150
o
F)
!
Storage Temperature Range
-40
o
C to 85
o
C (-40
o
F to 185
o
F)
!
Operating Humidity Range
5% to 95% non-condensing
!
Operating Vibration Limit
.04 g2/Hz 20-2000Hz
!
Operating Shock Limit
30g, 11mS, Half Sine
!
Enclosure Material
UL Recognized Polycarbonate
!
Weight
13oz (364gms)
Power Requirements
!
Power supply
Linear type recommended
!
Operating Voltage Range
10VDC -28.5VDC
!
Maximum Average Current 5V/12V
150mA
!
Transient Protection (all terminals)
UL294
!
Reverse Voltage Protection
YES
!
Input Voltage (maximum data-0/1 lines)
28.5VDC
!
Input Voltage (maximum interface lines)
28.5VDC
Operating Parameters
!
Excitation Frequency
125KHz
!
Duty Cycle (alternate power level rate)
20% @ 60mS period
!
Read and Report Speed (26 bit Wiegand Card)
175mS
!
Maximum Cable Distance to Host
500 feet (152 meters)
!
LED Type Bi-colored Red/Green
!
LED Operation (host control of red/green)
<.5V on LED control line
!
Beeper Operation (host control)
<.5V on beeper line
!
LED Control (default)
internal/single
!
Beeper Control (default)
Beeper enabled
!
Anti-Pass Back Delay (default)
1 second
!
Wiegand Data Pulse Widths (default)
40uS
!
Wiegand Data Interval (default)
2mS
Note: The above are recommended installation procedures. All local, state and national electrical
codes have precedence
codes have precedence