 –  ProxTrak Portal Reader Installation Procedure    6042-901-01 Rev 7              
10 of 32
spacer combinations (4 each) should be mounted at the 4 mounting locations listed in the Portal picture in
the “Reader dimension drawing”, above.
The inside cover of each of the Panels will have to be removed to facilitate installing the lag bolts into the
installation holes.
For some installations it may be necessary to replace the lag bolts with longer machined bolts, and mount
clear through to the other side of the wall for a more secure mount.
Other Doorways may be wider or narrower than the Portal dimensions. In these cases, the installations
may require adapter brackets mounted to the Portal at the 4 locations. These brackets could then be used
for doing an inside mount on the doorway, or outside mounts on the wall.
4.  System Checkout and Test
4.1  Power Supply Check
Power up the system and check the system voltages per Table 1
A1-A1 DSP Board
A1-A2 Exciter Assembly
U1-5
+5 VDC +/- .1 VDC
+40 VDC
+/- 1 VDC
U1-12
+3.3VDC +/- .05VDC
-40 VDC
+/- 1 VDC
U1-18
+2.5VDC +/- .05VDC
A2-A5 Sensor Bd
A3-A3 Sensor Bd
P1-1
+12 VDC
+/- .5VDC
P1-1
+12 VDC
+/- .5VDC
4.2 Exciter Tuning
Procedure to tune exciter and check exciter current
4.3 Receiver Null
Procedure to check receiver antenna nulls and tuning
4.4 System Performance
With the AMT100 included in the accessory kit test the read performance of the portal (put in free running
mode and power up).  Also check the performance with the access card
5.  Installation into an Asset Management System
5.1  Input and Output Signal Information
All cabling into and out of the portal must be shielded type cable, Alpha 129XC or similar.  The connectors
must be AMP 6749810 series or an exact replacement.
5.1.1  Serial cable for Host communications
The communication cable is connected to connector P10 on the DSP Bd Assembly.  This is a DB-9 style
connector.
5.1.1.1  Maximum Cable Lengths
RS485  4000 feet (1230 meters)
RS232 150 feet (46  meters).