3.5  Door Frame Mounting
3.5.1  Installation Accessory Kit
Each unit will be supplied with an installation accessory kit containing the following:
Mounting screws
Mounting washers
Mounting spacers
Cable egress/fitting kit
3.5.2  Mechanical Mounting Procedure
The Portal requires a external support structure such as a doorway frame, a structural wall nearby or
external supports designed to support the Portal frame from movement caused by incidental forces such
as people, carts, dollies or other items that may come into contact with the Portal in general use.  The
most common method of mounting is attaching the Portal to the doorframe. This method includes
positioning the Portal Reader close to the doorframe, allowing for a direct mount to the framework via the
appropriate fasteners for wood, steel or aluminum.
With this mounting method, the doorframe must be 35 to 41 inches inside width for an effective mounting
structure. The AC line cord must not exit on the face of the Portal frame that will be used for mounting. The
position of the AC cord can be specified at the time of ordering. An example of a doorframe mount is
shown below.
Portal Threshold
Portal
Uprights
1/2" Spacers
Door Frame
Door
Washer
Upright
Lag bolt
Spacer
Wall
Door frame mount - viewed from the top
Upright/door
frame detail
Definition of “exit” and “entrance” - Since the Portal is mostly used as an exit reader, you enter the Portal
on the end away from the door, and you exit the Portal at the doorway end. The two uprights that are on
the exit end of the Reader are devoid of cables between in a certain span of 51 inches in the center of the
vertical dimensions of the Portal. This is the space available for mounting the Portal to the doorframe. Lag
bolts, washers and the spacers (See insert) are included with the Accessory kits. The Lag bolts, washer,