HID Global Corporation 6042AA Manuale Utente

Pagina di 32
_________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600  (800) 237-7769  FAX (949) 598-1690
Web page – 
www.proxtrak.com
 –  ProxTrak Portal Reader Installation Procedure    6042-901-01 Rev 7              
16 of 32
6.11 Diagnostics
6.11.1  Set Calibration command
The Reader performs an auto-calibrate of all receivers and returns a Calibration response, which includes
the Exciter phase value.
6.11.2  Status Request Command
The Reader responds with a Data block message which includes the Status byte and a noise byte. The
Status byte includes information about the last acquisition status and a set of error codes. The noise byte
is an indication of the number of transitions in the receiver cycle during the highest exciter level and the
most significant bit represents an alert that the MAUI delays had to be activated as a result of an
interfering 125kHz interference.
6.11.3 H/W Configuration
The Hardware configuration command tests the switch blocks and returns switch settings in the H/W
Configuration response message.
6.11.4 Reset Command
Sending a $0D command resets the Reader.